Why the heating element storaged long time in the warehouse will be broken

Aug 30, 2023

Leave a message

 

When some customers order  heating elements,there are some spare heating element indle in the warehouse.

 

They will take them out when needed.But the placement time should not be too long.

 

Below,we will give you a analysis the reasons:

 

As the magnesium oxide powder in the heater element will absorb water, and the heating tube port is not completely sealed, the water will enter the electric heater element after being placed in a humid environment for a long time. At this time, the magnesium oxide powder  is damp, so the electric heater element will not heat up.

 

Analysis of the situation:

 

1. Measure if there is a resistance value, if no is broken.

 

2.If there is a resistance value, then see if there is no leakage phenomenon, use a megohm meter (insulation resistance meter) to measure the insulation resistance value, (the greater the insulation resistance value, the better the insulation) if the insulation resistance value is relatively small, it indicates that the magnesium oxide powder in the heating element may be affected by moisture, resulting in weak insulation of the electric heater!

 

Solution:

 

(1) Put the electric heater element in the oven to dry and dehumidify the magnesium oxide powder.

(2) Use low voltage to power the heating element for a while, which also plays a role in dehumidification.

 

 