Let's take an example: 220V, 1000W electric heating element respectively received 110V, 220V and 380V voltage on the difference.


According to the formula: voltage * voltage = resistance * power, when an electric heating element after its resistance is constant value, this time the voltage and power is directly proportional.

So let's figure out its resistance: 220*220/1000=48.4 ohms


When it is connected to 110V voltage, the power is: 110*110/48.4=250W

When it is connected to 380V voltage, the power is: 380*380/48.4=2983W


From the above calculation, we can know that when the 220V/1000W electric heating element is connected to the 110V voltage, the power of the electric heating pipe is 250W, and the power is reduced by 4 times. At 380V, the power is 2983W, which is three times the original power.


We all know that the life of the electric heating element is closely related to the surface load of the electric heating tube. The greater the surface load, the shorter the service life of the electric heating tube. Therefore, it can be known that the electric heating tube can prolong the service life by reducing the voltage.