1. Power design of boiler heating element
In the design of boiler electric heater,we must control its surface load, scale serious areas, one meter of boiler electric heating pipe power can not exceed 2KW.
2.The use of appropriate boiler heater tube material
If more scale is heated, it is recommended to use acid and alkali resistant materials, such as stainless steel 316, which can resist weak acid and base and reduce the corrosion of scale. Or use 304+ corrosion resistant coating tube material, this coating is similar to the non-stick pan, can automatically off scale, can also manually remove the scale on the surface of the heater element without hurting the boiler electric heating tube.
3. Prevent the magnesium powder from being damp